Asset Operations Hub

Pilbara Operations · Western Australia · Mon 20 Apr 2026
2 critical faults active
Fleet Availability
73.3%
11 of 15 assets running
MTBF
214h
Mean time between failures
Open Work Orders
7
3 in-progress, 2 awaiting parts
Critical Faults
2
Require immediate action
Equipment Fleet (15 assets)
Asset ID
Type
Status
Location
Hrs Today
Fuel %
Last Inspection
VR-TRK-0447
Haul Truck
Running
Pit 3 — North Ramp
9.3h
74%
2026-04-18
VR-TRK-0512
Haul Truck
Running
Haul Road — Section 7
11.1h
51%
2026-04-17
VR-TRK-0389
Haul Truck
Degraded
Pit 1 — South Face
7.6h
63%
2026-04-15
VR-TRK-0601
Haul Truck
Down
Workshop Bay 2
28%
2026-04-19
VR-TRK-0433
Haul Truck
Idle
Fuel Bay — Pad 3
97%
2026-04-20
VR-TRK-0558
Haul Truck
Running
Pit 2 — East Wall
8.7h
44%
2026-04-16
VR-TRK-0471
Haul Truck
Running
Haul Road — Section 3
10.2h
38%
2026-04-19
VR-TRK-0622
Haul Truck
Running
Pit 3 — South Ramp
9.9h
56%
2026-04-18
VR-EXC-0119
Excavator
Running
Pit 1 — Bench 4
10.4h
61%
2026-04-17
VR-EXC-0204
Excavator
Running
Pit 2 — Bench 2
9.1h
48%
2026-04-18
VR-EXC-0331
Excavator
Degraded
Pit 3 — Bench 1
6.3h
72%
2026-04-14
VR-CRU-0087
Crusher
Running
Crusher Station 1
12h
100%
2026-04-19
VR-CRU-0142
Crusher
Running
Crusher Station 2
11.7h
100%
2026-04-20
VR-CNV-0053
Conveyor
Running
Primary Circuit — CV-01
12h
100%
2026-04-20
VR-CNV-0091
Conveyor
Running
Secondary Circuit — CV-03
11.4h
100%
2026-04-19
Active Fault Alerts
VR-TRK-060106:23
Transmission fault code TX-447 — vehicle non-operational
VR-TRK-038907:41
Engine overtemperature warning — sustained 118°C (limit 110°C)
VR-EXC-033108:09
Hydraulic system pressure low — 241 bar (nominal 250–320)
VR-EXC-033108:14
Swing bearing displacement exceeding tolerance (0.6 mm vs <0.5 limit)
VR-TRK-038909:07
FL tyre pressure below lower bound — 776 kPa (minimum 800)